This cable can be used to connect 2 x AUDIOROOT eSMART batteries on a BG-DU or BG-DU-REG for simultaneous use or hotswapping.
Important notes :
- As this cable is passive the BG-DU will display battery telemetry from only 1 battery when 2 batteries are connected. The battery from which battery info is read is selected randomly (first battery to respond to smbus master commands).
- It is always the battery with highest voltage which handles the load. As the batteries’ voltage balance themselves during use they will tend to share the load 50/50.
At that point current and power information shown on the BG-DU will correspond to half the actual values and estimated runtime will be correct.
Overall length : 60cm – custom lengths on request